TRAINING OBJECTIVES
• Rate coefficient determination.
• Jet trajectory stud.
• Rated coefficient determination for every size of a nozzle.
• Different nozzle comparison.
• Water jet comparison.
• Identification of the factor responsible for water column height changing.
TECHNICAL DATA
Tank:
• Cylindrical tank: Ø 160mm x 500mm
• Maximum water height: 410mm
Measurement system:
• 8 measurement rods with back ruler.
Nozzles
• Ø 3 nozzle
• Ø 6 nozzle
ORIFICE AND FREE JET FLOW
This system is designed to study the output flow by holes disposed to get out horizontally.
The water tank has an adjustable height, so that test under different pressure conditions can be performed.
The tank has a level which indicates in every moment the height of the liquid.
Along with the possible horizontal jet trajectory, there are 8 vertical moving needles that are adjustable to follow the path of the jet, allowing a very easy measurement of the jet height.
Every nozzle is levelled with the inner surface of the tank, thus having minimal possible disruptions.
Moreover, the device has adjustable legs and a bubble level for proper system leveling.